NEK606 Water Blocked Offshore & Marine Cables  

NEK606 Water Blocked Offshore & Marine Cables

Water Blocked P16 IFLI 250 V

Applications

  • These cables are flame retardant, low smoke and halogen free, used for living, quarter and office areas.

Standards

  • IEC 60092-376 IEC 60092-351
    IEC 60092-359 IEC 60332-1
    IEC 60332-3-22 IEC 60754-1,2
    IEC 61034-1,2 NEK 606:2004
    VG 95218 part 29?  
Water Blocked P16 IFLI 250 V

Construction

  • l???? Conductors: Circular stranded copper wire to IEC 60228 class 2.
    l???? Insulation: XLPE.
    l???? Filler: Water blocking fillers, if required.
    l???? Bedding: Halogen free thermoplastic compound.
    l???? Metal Screen: Longitudinal aluminium tape, thickness 0.2 mm in contact with a stranded copper earth conductor, PETP wrapping tape will be applied over the bedding, if required.
    l???? Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness.
    l???? Inner Sheath: Halogen free thermoplastic compound, SHF1, coloured grey.
    l???? Outer Sheath: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low smoke standard.

Electrical Characteristics

  • Nominal Cross Section Area mm2 2.5
    Maximum Resistant@20˚C O/km 7.41
    Continuous Current Rating@45˚C2 Core A 26
    Short Circuit Current 1s A 360
    Operating Voltage V 250

Mechanical and Thermal Properties

  • Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
  • Temperature Range : -20˚C ~ +90˚C.

Dimensions and Weight

Construction
No. of elements×No. of cores in element×Cross section(mm2)

Nominal
Insulation Thickness mm

Nominal
Bedding Thickness mm

Nominal
Inner Sheath Thickness mm

Nominal
Outer Sheath Thickness mm

Nominal
Overall Diameter mm

Nominal Weight

kg/km

2×1×2.5

0.7

1.1

1.2

1.0

12.0±2

189